Energy Management System · EMS v1.5.0

Enterprise EMS Energy Management System
From Sensing to Reporting, in One System

An enterprise platform integrating SCADA visualization, coordinated dispatch, automatic control, COP efficiency optimization and government reporting. Built entirely on an open-source stack — no license fees, no vendor lock-in, fully offline deployment supported.

7
Core Function Modules
500–2000
Monitoring points by design
100%
Open-source tech stack
Air-gap
Offline deployment supported
Why You Need It

Energy Management Should Be More Than Meter Reading

Regulations tighten every year, electricity and carbon costs keep rising, yet equipment is scattered and hard to monitor centrally. What enterprises really need is a platform that links real-time monitoring → efficiency analysis → automatic control → one-click reporting into a single chain, not isolated meters plus a pile of spreadsheets.

📊

See It

SCADA single-line diagrams show chillers, pumps and cooling towers' operating status and consumption in real time — the whole plant at a glance.

🎯

Save It

Instantaneous and system COP and kW/RT are calculated live, low-efficiency equipment is flagged automatically, and energy-saving control strategies follow.

📑

Report It

Energy audit, savings-rate and REO reporting templates are built in, with digital signatures and an audit chain — keeping pace with regulatory deadlines.

Capabilities

Seven Core Function Modules

A complete closed loop from data acquisition to government reporting — every link auditable, traceable and extensible.

🖥️

Visualization / SCADA

Single-line diagrams and writable point control (switching, setpoints); commands are released only after RBAC authorization and two-person review.

🔗

Coordinated Control / DERMS

Resource portfolios, constraint panels, actionable dispatch recommendations and scenario simulation to orchestrate energy resources across multiple sites.

⚙️

Automatic Control

PID, logic and schedule governance with version rollback and fail-safe degradation on connection loss, keeping the site safe under any condition.

📈

COP Efficiency Calculation

Instantaneous COP, kW/RT and system COP computed in real time and fed directly into energy-saving optimization decisions.

🚨

Smart Alarms

First-out detection, acknowledgment, suppression and deadband/delay debouncing, aligned with the ISA-18.2 alarm management standard.

🏛️

Reporting Gateway

Energy audit, savings, REO and monthly reports generated in one place, with X.509 digital signatures and a full audit chain.

📡

Unified MQTT Data Acquisition

Devices and gateways publish directly to EMQX over MQTT 5.0, following a one-entity-one-topic, flat-payload standard; devices self-describe on connection and points are created automatically. Legacy non-MQTT equipment connects through an on-site gateway — no plant-wide replacement needed.

Efficiency Core

Find Savings with Data

The system computes chiller efficiency metrics in real time, quantifying every unit and every refrigeration group — so savings are evidence-based and verifiable, not tuned by feel.

COP
Chiller / System Efficiency Ratio
Chiller COP = cooling capacity ÷ compressor power; System COP = cooling capacity ÷ total power (compressor + pumps + cooling tower).
kW/RT
Power per Refrigeration Ton
Refrigeration tons RT = cooling capacity ÷ 3.517, converting each ton of cooling directly into electricity cost.
Load Ratio
Equipment Operating Efficiency
Real-time load ratio = current RT ÷ rated RT, exposing oversized units running inefficiently at partial load.
Value Chain

Sensing → Data → Analysis → Control → Savings → Verification

An end-to-end energy management loop, every stage standardized and auditable.

📡 Devices / Gateways MQTT (EMQX) Backend ingest Time-series + master DB SCADA / Analytics / Alarms Automatic Control 🏛️ Government Reporting
Architecture

Fully Open-Source, Enterprise-Grade, Offline-Capable

Built on mature open-source components with no license fees or vendor lock-in, supporting fully air-gapped offline deployment.

EMQX 5.xMQTT 5.0 message bus · ACL · mTLS
InfluxDB 2.xHigh-compression time-series database
PostgreSQL 16 + TimescaleDBMaster data · Commands · Reporting · Audit
Node-RED 4Rule-based alarms · Report scheduling
FastAPI (Python 3.12)COP · Commands · RBAC · Reporting
Vue 3 + NginxSCADA / dispatch front-end · TLS gateway
Docker ComposeOne-click deploy · hotfix · rollback
Edge SimulatorPython + paho-mqtt test data
Compliance

Mapped to Taiwan Energy Regulations and International Standards

Implemented per the Large-Scale EMS Design Report, covering major regulatory filings plus international standards for cybersecurity and energy management.

Regulation / StandardSystem Capability
Energy Administration ActMonitoring / history / reports / master data / energy managers / sub-metering / audit trail
FY114–117 Energy-Saving RulesThree-tier HQ → site → meter-ID structure with cross-site savings KPIs
Energy Use Data ReportingAnnual / monthly / multi-type reports with built-in templates and validation
Renewable Energy Obligation RulesImplementation plans / operating data / corrections
Electronic Signatures ActX.509 signing service / certificate management / digests / timestamps
Cyber Security Management ActISMS / zoning and segmentation / audit logs to SIEM
International StandardsISO 50001 / 50006 · IEC 61850 / 62351 / 62443 · OPC UA · ISA-18.2 / ISA-101
Why Choose Us

Benefits

💰

Low Adoption Cost

Fully open-source stack with no software license fees; one-click Docker deployment cuts integration hours too.

🔒

Security & Audit

RBAC role separation, two-person review and a complete audit chain, meeting Cyber Security Management Act requirements.

🧩

Scalable Architecture

Standardized MQTT onboarding — add devices or sites without changing the architecture, and scale horizontally as the business grows.

🛰️

Works Offline

Air-gapped offline package deployment for isolated OT networks — no need to change security policy just to go to the cloud.

🔧

Field-Ready

Self-describing devices, automatic point creation and direct SCADA control, matching the way field engineers already work.

🔄

Rollback-Safe

Semantic versioning plus per-service hotfixes — roll back in seconds when something goes wrong, so operations can breathe easy.

Turn Energy Management into a Competitive Edge

From a single-site pilot to multi-plant rollout, we provide system build-out, device onboarding, training and reporting support. Bring your site conditions and let's assess feasibility together.

Enterprise EMS Energy Management System v1.5.0 · Product Overview
SCADA Visualization DERMS Coordinated Control COP Efficiency Optimization Government Reporting Gateway MQTT 5.0 ISO 50001 IEC 62443